Crane FEM Consulting

MARK-36 Portal Crane Structural Analysis

LOCATION
Ukraine
CRANE
MARK-36 Portal Level Luffing Boom Crane
PROJECT
Structural Design
CUSTOMER
KONECRANES Ukraine

PROJECT OVERVIEW

The Challenges

Structural design of a new portal level luffing boom crane “MARK-36” for KONECRANES Ukraine was performed using FEM 1.001. The FEM analysis included checks of wheel forces, static strength, fatigue and buckling. Based on the obtained results, the necessary reinforcement proposals were developed

FINITE ELEMENT ANALYSIS

Structural Analysis of the MARK-36 Crane

STRUCTURAL VERIFICATION

Column Structural Assessment

>   Wheel Forces
FEM analysis was performed to determine wheel forces and verify load distribution on the portal structure.
>   Static Strength
Static strength analysis was carried out to verify the structural integrity of the main components.
>   Fatigue
Fatigue analysis was performed to assess the crane structure under cyclic loading conditions.
>   Buckling
Buckling analysis was carried out to verify stability of critical elements.

PROJECT OUTCOME

Structural Reinforcement Assessment

The structural design and FEM assessment of the new MARK-36 portal level luffing boom crane included verification of wheel forces, static strength, fatigue and buckling. Based on the obtained analysis results, the necessary reinforcement proposals were developed