Structural Assessment of LIEBHERR Deck Crane
Structural assessment of a LIEBHERR deck crane to validate the use of an equivalent steel grade for jib repair and obtain classification society approval.

Structural assessment of a LIEBHERR deck crane to validate the use of an equivalent steel grade for jib repair and obtain classification society approval.
Structural assessment to verify safe operation of a portal boom crane with a 40-ton lifting capacity across the full working outreach.
Structural engineering support for a third-party RTG crane height increase from 18 to 21 meters. The project included fatigue, buckling, and static strength analysis, crane stability verification, and the design of additional leg sections, exhaust pipe extension, and tie beam reinforcement in accordance with BS 2573.
Comprehensive condition assessment of a 1976 ship-to-shore crane, including structural analysis, material evaluation, stress measurements, and remaining service life estimation.
Structural assessment of a quay crane trolley frame as part of a major crane rehabilitation project, identifying overloaded members with potential fatigue, cracking, and plastic deformation.
Independent assessment of structural repairs on four quay cranes based on strain gauge and accelerometer measurements collected before and after the repair
Comprehensive structural survey and engineering assessment of two ship-to-shore cranes under operational loading conditions, including inspection of critical structural members and recommendations for continued safe operation.
Structural design and finite element analysis of a portal level-luffing boom crane structure for safe operation under specified lifting and wind loads.
Comprehensive structural inspection of a quay crane to identify deformation, assess structural integrity, determine root causes of damage, and provide recommendations for repair and continued safe operation.
Technical feasibility study aimed at increasing ship loader productivity. The project included structural assessment, equipment verification, operational load analysis, and recommendations for safe capacity improvement.